Table B-115.6” LCD Monitors (continued)

Environmental Requirements

 

 

Temperature

 

 

Operating Temperature

0° to 40° C

32° to 104° F

 

 

Storage Temperature

-20° to 60° C

-4° to 140° F

 

 

 

 

 

Relative Humidity (LV1561w, LV1561ws, and

 

 

CQ1569 models)

 

 

Operating

10% to 85% (non-condensing)

 

Non-operating

5% to 80% (non-condensing)

 

Relative Humidity (LV1561x and CQ1569x

 

 

models)

 

 

Operating

20% to 85% (non-condensing)

 

 

 

Non-operating

10% to 85% (non-condensing)

 

 

 

 

 

 

Power Source (LV1561w, LV1561ws, and

100 ~ 240 VAC, 50/60 Hz

 

CQ1569 models)

 

 

 

Power Source (LV1561x and CQ1569x models)

100–240 VAC, 50/60 Hz

 

 

 

Measured Power Consumption (LV1561x and

 

 

CQ1569x models with LED Backlight):

 

 

Full Power

12 W

 

Typical Settings

10 W

 

Sleep

2 W

 

Switch Off

1 W

 

 

 

 

Altitude (LV1561w, LV1561ws, and CQ1569

 

 

models)

 

 

Operating

0 ~ 3000 m

0 ~ 10000 ft.

Non-operating

0 ~ 5000 m

0 ~ 15000 ft.

Altitude (LV1561x and CQ1569x models)

 

 

Operating

0–3000 m

0–9842 ft.

Non-operating

0–5000 m

0–16404 ft.

 

 

 

Recognizing Preset Display Resolutions

The display resolutions listed below are the most commonly used modes and are set as factory defaults. This monitor automatically recognizes these preset modes and they will appear properly sized and centered on the screen.

Table B-2Factory Preset Modes

Preset

Pixel Format

Horz Freq (kHz)

Vert Freq (Hz)

 

 

 

 

1

640 × 480

31.47

59.94

 

 

 

 

2

800 × 600

37.88

60.32

 

 

 

 

3

1024 × 768

48.36

60.00

 

 

 

 