HP M2519TU, M2599XX, M2526TU manual Typical Electrostatic Voltage Levels, Static-Shielding Materials

Models: M2200 M2525TU M2527TU M2501TU M2261TU M2267TU M2504TU M2523TU M2529TU M2273TU M2521TU M2520TU M2246AP M2251AP M2507TU M2265TU M2510TU M2513TU M2274TU M2515LA M2522TU M2254AP M2425LA M2276TU M2277TU M2258TU M2502TU M2508TU M2514TU M2263TU M2517TU M2599XX M2257TU M2500 M2519TU M2528TU M2250AP M2503TU M2505TU M2262TU M2526TU M2506TU M2516TU M2259TU M2512TU

1 239
Download 239 pages 2.49 Kb
Page 100
Image 100

Removal and Replacement Preliminaries

Table 4-1 shows how humidity affects the electrostatic voltage levels generated by different activities.

Table 4-1

Typical Electrostatic Voltage Levels

Relative Humidity

Event

10%

40%

55%

 

 

 

 

Walking across carpet

35,000 V

15,000 V

7,500 V

 

 

 

 

Walking across vinyl floor

12,000 V

5,000 V

3,000 V

 

 

 

 

Motions of bench worker

6,000 V

800 V

400 V

 

 

 

 

Removing DIPS from plastic tube

2,000 V

700 V

400 V

 

 

 

 

Removing DIPS from vinyl tray

11,500 V

4,000 V

2,000 V

 

 

 

 

Removing DIPS from Styrofoam

14,500 V

5,000 V

3,500 V

 

 

 

 

Removing bubble pack from PCB

26,500 V

20,000 V

7,000 V

 

 

 

 

Packing PCBs in foam-lined box

21,000 V

11,000 V

5,000 V

A product can be degraded by as little as 700 V.

Table 4-2 lists the shielding protection provided by antistatic bags and floor mats.

Table 4-2

Static-Shielding Materials

Material

Use

Voltage Protection Level

 

 

 

Antistatic plastic

Bags

1,500 V

 

 

 

Carbon-loaded plastic

Floor mats

7,500 V

 

 

 

Metallized laminate

Floor mats

5,000 V

 

 

 

4–8

Maintenance and Service Guide

Page 100
Image 100
HP M2519TU, M2599XX Typical Electrostatic Voltage Levels, Static-Shielding Materials, Relative Humidity Event 10% 40% 55%