Preface

Safety and regulatory information

For your protection, this product has been tested to various national and international regulations and standards. The scope of this regulatory testing includes electrical/mechanical safety, radio frequency interference, acoustics, and known hazardous materials. Where applicable, approvals obtained from third-party test agencies are shown on the product label.

Notational conventions

Warning:

Warnings highlight procedures or information necessary to avoid injury to personnel. The warning should tell the reader exactly what will result from what actions and how to avoid them.

Caution:

A caution highlights procedures or information necessary to avoid damage to equipment, damage to software, loss of data, or invalid test results.

Note:

A note highlights supplemental information.

Acronyms and abbreviations

Acronym/

 

Acronym/

 

abbreviation

Definition

abbreviation

Definition

 

 

 

 

BSPP

British Standard Pipe Parallel

NPT

National Pipe Thread

 

 

 

 

CHWS

Chilled water supply

NPTF

American National taper pipe thread for

 

 

 

dry-seal pressure-tight joints

 

 

 

 

CHWR

Chilled water return

MCS 5042

mc-Series 5042 Rack

 

 

 

 

CTO

Configure to order

PTFE

Polytetrafluoroethylene

 

 

 

 

FRU

Field Replaceable Unit

TN Grounding

Grounding specification

 

 

 

 

HEX

Heat Exchanger Unit

GOW

Gas, oil, water

 

 

 

 

LAHJ

Local Authority Having Jurisdiction

WSP

Water steam pressure

 

 

 

 

2

Page 2
Image 2
HP Modular Cooling System Preface, Safety and regulatory information, Notational conventions Acronyms and abbreviations

Modular Cooling System specifications

The HP Modular Cooling System (MCS) is a state-of-the-art solution designed to efficiently manage the heat generated by high-density IT environments. As data centers face the ever-increasing demand for processing power, traditional cooling methods often fall short, leading to inefficiencies and raised energy costs. The HP MCS addresses this issue with a scalable, flexible design that optimizes cooling performance while minimizing energy consumption.

One of the main features of the HP Modular Cooling System is its modular architecture, which allows for easy expansion and customization based on the specific needs of a data center. This scalability means that as a facility grows or changes, the cooling system can be modified without the need for extensive renovations or replacements. The MCS can be installed in various configurations, further enhancing its versatility.

The technology behind the HP MCS includes advanced cooling methods such as direct evaporative cooling and chilled water cooling. Direct evaporative cooling utilizes the principles of evaporative heat exchange to cool air without excessive energy consumption, making it an eco-friendly choice. In contrast, chilled water cooling uses a network of pipes filled with chilled water to remove heat from the server environment efficiently. This combination allows the MCS to adapt to various heat loads and ambient conditions.

Another notable characteristic of the HP Modular Cooling System is its intelligent controls and sensors. These components continually monitor temperature and humidity levels within the data center, automatically adjusting cooling output to maintain optimal conditions. This proactive approach helps to prevent overheating, reduces energy usage, and ensures the longevity of IT equipment.

Energy efficiency is further enhanced through the MCS's integration with HP's monitoring and management software. This software analyzes cooling performance trends, providing actionable insights for facility managers, enabling them to make informed decisions regarding cooling strategies. Additionally, the system is designed with environmentally sustainable practices in mind, aligning with global initiatives to reduce carbon footprints and promote green technology.

The HP Modular Cooling System stands out for its combination of innovative technologies, flexibility, and a commitment to energy efficiency. As data centers continue to evolve, the MCS remains a crucial asset in the pursuit of optimized performance and sustainability, providing a reliable solution to meet the demanding cooling needs of modern IT infrastructure.