HP Modular Cooling System manual Regulatory information

Models: Modular Cooling System

1 93
Download 93 pages 20.21 Kb
Page 87
Image 87

Under NRC regulations, a general licensee using tritium EXIT signs:

must NOT remove the labeling or radioactive symbol, or abandon a sign;

must properly dispose of an unused sign (see below);

must report to the NRC or the appropriate Agreement State any lost, stolen or broken signs;

must inform the NRC or an Agreement State of a name change, change of address or replacement of a general licensee’s designated representative;

must NOT give away or sell the sign to another individual, company or institution unless the device is to remain in use at its original intended location; in such a case, the transferor is to notify the recipient of the regulatory requirements and must notify the NRC or Agreement State of the transfer within 30 days.

Tritium EXIT signs must NOT be disposed of as normal trash. To dispose of a sign properly, a general licensee must transfer the sign to a specific licensee. This would typically be a manufacturer, distributor, licensed radioactive waste broker, or a licensed low-level radioactive waste disposal facility. These facilities may charge a fee for this service.

Within 30 days of disposing of a sign, the general licensee is required to file a report to the NRC or Agreement State that includes:

the device manufacturer’s (or distributor’s) name, model number and serial number;

the name, address, and license number of the person receiving the device; and

the date of the transfer.

Reports should be sent to Director, Office of Federal and State Materials and Environmental Management Programs, ATTN: GLTS, U.S. Nuclear Regulatory Commission, Washington, D.C. 20555-0001.

For more information, see the Fact Sheet on Tritium EXIT Signs on the NRC website (http://www.nrc.gov/reading-rm/doc-collections/fact-sheets/fs-tritium.html).

Regulatory information 87

Page 87
Image 87
HP Modular Cooling System manual Regulatory information

Modular Cooling System specifications

The HP Modular Cooling System (MCS) is a state-of-the-art solution designed to efficiently manage the heat generated by high-density IT environments. As data centers face the ever-increasing demand for processing power, traditional cooling methods often fall short, leading to inefficiencies and raised energy costs. The HP MCS addresses this issue with a scalable, flexible design that optimizes cooling performance while minimizing energy consumption.

One of the main features of the HP Modular Cooling System is its modular architecture, which allows for easy expansion and customization based on the specific needs of a data center. This scalability means that as a facility grows or changes, the cooling system can be modified without the need for extensive renovations or replacements. The MCS can be installed in various configurations, further enhancing its versatility.

The technology behind the HP MCS includes advanced cooling methods such as direct evaporative cooling and chilled water cooling. Direct evaporative cooling utilizes the principles of evaporative heat exchange to cool air without excessive energy consumption, making it an eco-friendly choice. In contrast, chilled water cooling uses a network of pipes filled with chilled water to remove heat from the server environment efficiently. This combination allows the MCS to adapt to various heat loads and ambient conditions.

Another notable characteristic of the HP Modular Cooling System is its intelligent controls and sensors. These components continually monitor temperature and humidity levels within the data center, automatically adjusting cooling output to maintain optimal conditions. This proactive approach helps to prevent overheating, reduces energy usage, and ensures the longevity of IT equipment.

Energy efficiency is further enhanced through the MCS's integration with HP's monitoring and management software. This software analyzes cooling performance trends, providing actionable insights for facility managers, enabling them to make informed decisions regarding cooling strategies. Additionally, the system is designed with environmentally sustainable practices in mind, aligning with global initiatives to reduce carbon footprints and promote green technology.

The HP Modular Cooling System stands out for its combination of innovative technologies, flexibility, and a commitment to energy efficiency. As data centers continue to evolve, the MCS remains a crucial asset in the pursuit of optimized performance and sustainability, providing a reliable solution to meet the demanding cooling needs of modern IT infrastructure.