Step 2: Mark the Rack Column Holes

Use tape or a marking pen to mark the screw holes where you will install the barrel nuts:

On each rear rack column, mark the top and bottom holes of the EIA unit on the inside of the column, as shown in Figure 7 and Figure 8.

On each front rack column, mark the hole on the middle of the EIA unit on the inside of the column.

Step 3: Place the Barrel Nuts on the Rack Columns

1.Identify the six barrel nuts by referring to Figure 7 and Figure 8.