HP Smart Array Advanced Pack Software manual Abnormal termination of a rebuild

Models: Smart Array Advanced Pack Software

1 100
Download 100 pages 45.58 Kb
Page 85
Image 85

Abnormal termination of a rebuild

If the activity LED on the replacement drive permanently ceases to be illuminated even while other drives in the array are active, the rebuild process has terminated abnormally. The following table indicates the three possible causes of abnormal termination of a rebuild.

Observation

Cause of rebuild termination

 

 

None of the drives in the array have an

One of the drives in the array has

illuminated amber LED.

experienced an uncorrectable read error.

The replacement drive has an

The replacement drive has failed.

illuminated amber LED.

 

One of the other drives in the array has

The drive with the illuminated amber LED has

an illuminated amber LED.

now failed.

Each of these situations requires a different remedial action.

Case 1: An uncorrectable read error has occurred.

1.Back up as much data as possible from the logical drive.

CAUTION: Do not remove the drive that has the media error. Doing so causes the logical drive to fail.

2.Restore data from backup. Writing data to the location of the unreadable sector often eliminates the error.

3.Remove and reinsert the replacement drive. This action restarts the rebuild process.

If the rebuild process still terminates abnormally:

1.Delete and recreate the logical drive.

2.Restore data from backup.

Case 2: The replacement drive has failed.

Verify that the replacement drive is of the correct capacity and is a supported model. If these factors are not the cause of the problem, use a different drive as the replacement.

Case 3: Another drive in the array has failed.

A drive that has recently failed can sometimes be made temporarily operational again by cycling the server power.

1.Power down the server.

2.Remove the replacement physical drive (the one undergoing a rebuild), and reinstall the drive that it is replacing.

3.Power up the server.

If the newly failed drive seems to be operational again:

1.Back up any unsaved data.

2.Remove the drive that was originally to be replaced, and reinsert the replacement physical drive. The rebuild process automatically restarts.

3.When the rebuild process has finished, replace the newly failed drive.

However, if the newly failed drive has not recovered:

1.Remove the drive that was originally to be replaced, and reinsert the replacement physical drive.

2.Replace the newly failed drive.

Drive procedures 85

Page 85
Image 85