| Doc. No. | REV. | |
| HTC Corporation. |
|
|
|
| Issued Date | 2008/12/29 | AX02 | |
| . |
|
| |
| Revised Date | 2009/01/14 | ||
|
| |||
|
|
| ||
|
|
|
|
|
Doc. Title | Sapphire Service Manual | Page | 55 of 91 |
Conclusion:
If current consumption is passed at both of flight and power off mode, it means M/B is
GOOD.
If there is any item FAILED at flight or power off mode, it means M/B is failed, please replace M/B for repair.
Measurement parameter
Measurement mode | Measured Current | REMARK | |
Flight Mode | Under mA | MB is good | |
|
| ||
Over 105 mA | Fail, MB need to be further | ||
(Idle mode) | |||
| repaired | ||
|
| ||
POWER OFF | Under 3 mA | MB is good | |
|
| ||
( Sleeping mode) | Over 3 mA | Fail, MB need to be further | |
|
| repaired | |
|
|
|
HTC CONFIDENTIAL