390CHAPTER 11: CONFIGURING AND MANAGING PNNI

Set UBR Sets the UBR Administrative Weight parameter. The UBR administrative Administrative weight is the administrative weight of this interface port for the

Weight unspecified bit rate service category.

Command Actions

Enter menu sequence:

(1) SYS: Platform Configuration

 

(1) SET: Switch setup

 

(9) PNI: PNNI Setup

 

(4) CFP: Configure PNNI

 

(4) ICF: Interface Configuration

 

(2) IPR: Interface Parameters

 

(6) UBW: UBR Admin Weight

Enter a parameter at the prompt

Parameter

Format or Range

UBR admin weight

1 - 2147483647

Direct access sequence:

1 1 9 4 4 2 6 [parameters]

Command Result

System action taken:

System message display:

.The UBR admin weight parameter is updated to its new value.

Default Value is 5040, New value is

set to <n>.

Example

Enter: 1 1 9 4 4 2 6 18000

The following message is displayed:

Default value is 5040, new value is set to 19000

Press ENTER to continue...

Page 390
Image 390
3Com 9000 manual Weight unspecified bit rate service category