386CHAPTER 11: CONFIGURING AND MANAGING PNNI

Set CBR Sets the CBR Administrative Weight parameter. The CBR administrative Administrative weight is the administrative weight of this interface port for the constant

Weight bit rate service category.

Command Actions

Enter menu sequence:

(1) SYS: Platform Configuration

 

(1) SET: Switch setup

 

(9) PNI: PNNI Setup

 

(4) CFP: Configure PNNI

 

(4) ICF: Interface Configuration

 

(2) IPR: Interface Parameters

 

(2) CBR: CBR Admin Weight

Enter a parameter at the prompt

Parameter

Format or Range

CBR admin weight

1 - 2147483647

Direct access sequence:

1 1 9 4 4 2 2 [parameters]

Command Result

System action taken:

System message display:

The CBR admin weight parameter is updated to its new value.

Default value is 5040, new value is

set to <n>

Example

Enter: 1 1 9 4 4 2 2 6000

The following message is displayed:

Default value is 5040, new value is set to 6000

Press ENTER to continue...

Page 386
Image 386
3Com 9000 manual Weight bit rate service category