Setting the Timers 369

Set SVCC Initiation Sets the SVCC initiation time. The SVCC initiation time is the time it takes Time to reinitiate a Switched Virtual Channel Connection after it has been

taken down. For more information on virtual channel connections, see “Virtual Channels” on page 84 in the Operations Guide. A change to the SVCC initiation time takes place after the next reboot.

Command Actions

Enter menu sequence:

(1) SYS: Platform Configuration

 

(1) SET: Switch setup

 

(9) PNI: PNNI Setup

 

(4) CFP: Configure PNNI

 

(3) NCF: Node Configuration

 

(4) TIM: Timers

 

(13) SIT: SVCC Initiation Time

Enter a parameter at the prompt

Parameter

Format or Range

initiation time

1 - 60000 seconds

Direct access sequence:

1 1 9 4 3 4 13 [parameters]

Command Result

System action taken:

System message display:

The SVCC initiation time is displayed and is updated to its new value.

Default value is <x>. New value is <y>

Example

Enter: 1 1 9 4 3 4 13 20

The following message is displayed:

Default Value is 4, new value is 20

Press ENTER to continue...