Setting the Timers 367
Set CDV Proportional
Multiplier (%) Sets the CDV proportional multiplier percentage. The CDV proportional
multiplier percentage is the percentage difference in the Cell Delay
Variation metrics from the last value advertised. A change to the CDV
proportional multiplier percentage value takes place after the next
reboot.
Command Actions
Command Result
Example
Enter: 1 1 9 4 3 4 11 15
The following message is displayed:
Default Value is 25, new value is 15
Press ENTER to continue...
Enter menu sequence: (1) SYS: Platform Configuration
(1) SET: Switch setup
(9) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(11) CDV: CDV Proportional
Multiplier(%)
Enter a parameter at the prompt
Parameter Format or Range
percentage 1 - 99%
Direct access sequence: 1 1 9 4 3 4 11 [parameters]
System action taken: The CDV proportional multiplier is displayed a nd is
updated to its new value.
System message display: Default value is <x>, new value is <y>