LAN Emulation Redundancy 269

Assign Redundant Assign a LES to be the redundant (secondary) LES of a specified ELAN in LES to ELAN the LECS database. Specify the ELAN name and the ATM address of the

LES. The secondary LES should reside on a different switch than the primary LES. For more information, see “LES Redundancy Facility — Configuring the ELAN Topology Database” on page 139 in the Operations Guide.

Command Actions

Enter menu sequence:

(2) LEM: LAN Emulation

 

(1) LCS: LE Configuration Service

 

(5) LNT: LECS Network topology

 

(9) RDN: LE Service redundancy

 

(1) ALS: Add redundant LES to

 

elan

Enter a parameter at the prompt

Parameter

Format or Range

ELAN name

Up to 32 characters. For more information, see “Add

 

ELAN” on page 259.

LES ATM address

20 Hex bytes separated by periods

Direct access sequence:

2 1 5 9 1 [parameters]

Command Result

 

System action taken:

The specified LES is assigned to be the secondary LES

 

for the specified ELAN in the LECS database.

System message display:

Redundant LES successfully added.

Example

Enter: 2 1 5 9 1 elan73_9

47.0.0.0.0.0.3c.0.0.d0.0.0.0.0.1.2.3.4.5.6

The following message is displayed:

Redundant LES successfully added.

The specified LES is assigned to be the secondary LES for the specified ELAN in the LECS database.

Page 269