Setting the Timers 359

Set Hello Interval Sets the Hello interval value. In the absence of triggered Hellos, the specified node will send one Hello packet on each of its ports every “interval” seconds. A change to the Hello interval value takes place after the next reboot.

Command Actions

Enter menu sequence:

(1) SYS: Platform Configuration

 

(1) SET: Switch setup

 

(9) PNI: PNNI Setup

 

(4) CFP: Configure PNNI

 

(3) NCF: Node Configuration

 

(4) TIM: Timers

 

(3) HIN: Hello Interval

Enter a parameter at the prompt

Parameter

Format or Range

interval

1 - 30000 seconds

Direct access sequence:

1 1 9 4 3 4 3 [parameters]

Command Result

System action taken:

System message display:

The Hello holddown timer values is displayed and is updated to its new value.

Default value is <x>, new value is <y>

Example

Enter: 1 1 9 4 3 4 3 5

The following message is displayed:

Default Value is 15 (15 sec), new value is 5

Press ENTER to continue...

Page 359
Image 359
3Com 9000 manual 9 4 3 4 3 parameters