186CHAPTER 7: CONFIGURING VIRTUAL CHANNELS

Table 25 SSCOP Timers (continued)

SSCOP Timer

Description

 

 

No-Response

Maximum time between receipt of a STAT PDU in an active

 

connection.

CCThe connection control timer determines the time between transmission of BGN, END, or RS PDUs, as long as an acknowledgment PDU has not been received.

For stability, make the timer No-Response greater than timer Keep-Alive, and make timer No-Response greater than timer Poll. Also, make timer No-Response and timer CC greater than the round trip delay.

SSCOP Configuration Parameters

Table 26 shows the SSCOP Configuration Parameters displayed by the command.

.

Table 26 SSCOP Configuration Parameters

SSCOP

Description

Parameter

 

 

MaxCC

Maximum value for the state variable VT(CC), corresponding to

 

the maximum number of transmissions of a BGN, END, or RS

 

PDU.

MaxPD

Maximum acceptable value for the state variable VT(PD) before

 

sending a POLL PDU and resetting VT(PD) to zero.

MaxSTAT

Maximum number of list elements permissible in a STAT PDU.

Window

Sequence number of the first SD or SDP PDU not allowed by the

 

receiver.

 

 