Signaling Timers 185

Display QSAAL Display the current QSAAL signaling protocol timer values and Service Signaling Timers and Specific Connection-Oriented Protocol (SSCOP) configuration parameters

Protocol for the specified port. The timer values are displayed in tenths of a Configuration second.

You can update the timer values by changing the timer resolution. For more information, see “Update Protocol Timer Resolution” on page 182. The configuration parameters can be altered.

Command Actions

Enter the menu sequence:

(1) SYS: Platform Configuration

 

(1) SET: Switch Setup

 

(4) SIG: Signaling Setup

 

(4) QSA: Get Signaling QSAAL

 

Configuration setup

Enter a parameter at the prompt

Parameter

Format or Range

Port number

<slot.group.port>

Direct access sequence:

1 1 4 4 [parameters]

Command Result

 

System action taken:

The current QSAAL signaling protocol timer values and

 

SSCOP configuration parameters for the specified port

 

are displayed.

System message display:

Information is displayed as shown in the example.

SSCOP Timers

Table 25 shows the SSCOP Timers displayed by the command.

Table 25 SSCOP Timers

SSCOP Timer

Description

 

 

Poll

The maximum time between transmission of a POLL PDU, when

 

SD or SDP PDUs are queued for transmission or are outstanding

 

pending acknowledgment.

Keep-Alive

Maximum time between transmission of POLL PDUs, when no

 

SD or SDP PDUs are queued for transmission or are outstanding

 

pending acknowledgment.

 

 

Page 185
Image 185
3Com 9000 manual Shows the Sscop Timers displayed by the command, QSA Get Signaling Qsaal, Configuration setup