182CHAPTER 7: CONFIGURING VIRTUAL CHANNELS

Update Protocol Update the timer resolution of the CoreBuilder 9000 ATM Enterprise Timer Resolution Switch. The default timer resolution is 500 msec (0.5 secs); the minimum

timer resolution is 100 msec and there is no upper limit. For more information, see the previous section and see “Timer Resolution” on page 98 in the Operations Guide.

This command causes the new timer resolution to be activated in the current session. The new value is stored in flash.

Command Actions

Enter the menu sequence:

(1) SYS: Platform configuration

 

 

 

(1) SET: Switch setup

 

 

 

(4) SIG: Signaling setup

 

 

 

(1) RES: Timer Resolution setup

 

 

 

(2) SET: Set Timer Resolution

Enter a parameter at the prompt

Parameter

 

 

Format or Range

Timer Resolution

in millisec; Range: >=100

Direct access sequence:

1 1 4 1 2 [parameters]

Command Result

 

System action taken:

The timer resolution is updated.

System message display:

Timer resolution was successfully set.

Example

 

 

 

Enter: 1 1 4

1

2 250

 

The following message appears:

Timer resolution was successfully set.

The timer resolution is updated to 250 msec and saved to flash.

Page 182
Image 182
3Com 9000 Timer resolution is updated to 250 msec and saved to flash, RES Timer Resolution setup, SET Set Timer Resolution