Create Permanent Virtual Channel (PVC) 157
Add PVC Destination Create an additional destination connection (branch) for an existing
point-to-multipoint PVC.
You can only create an additional destination if the exi sting PVC was
predefined as a PLM PVC.
Enter the call number of the original PVC setup and the parameters:
output port number, VPI/VCI and CLP, with the same permissible values.
Default values for Cell Loss Level, Priority, and Cell Loss Priority are used.
See Table23. The same limits as full PVC call setup apply.
You cannot add an additional PVC destinatio n to a P2P PVC.
Command Actions
Command Result
Enter the menu sequence: (3) CON: Connections
(4) S&C: Setup of Connections and ATM
Addresses
(1) PVC: PVCs Setup
(4) CRO: Create out VC in call
Enter a parameter at the prompt
Parameter Format or Range
Call number Integer
Output port number <slot.group.port>
Output port VPI See “Display PVC VPI/VCI Limits” on page 151 for
VPI/VCI limits.
Output port VCI See “Display PVC VPI/VCI Limits” on page 151 for
VPI/VCI limits.
Output port CLP 0 for clear
1 for set
Direct access sequence: 3 4 1 4 [parameters]
System action taken: An additional PVC destination with parameters
specified is created.
System message display: A new output VC was created
with call number: <n>
out connection number: <n>