LAN Emulation Redundancy 279

Redundant LES General Parameters

Table 38 describes the redundant LES general parameters.

Table 38 Redundant LES General Parameters

Parameter

Description

 

 

 

 

LES ATM Address

The LES ATM address.

 

Connection State

The LES connection state. This can be:

 

Establish

There is a connection between the

 

 

LECS and the LES.

 

Being Established

A connection is being established

 

 

between the LECS and the LES.

 

No Connection

There is no connection between the

 

 

LECS and the LES.

LES Location

The location of the LES. This can be: Internal or External.

 

Internal

The LES is on the same switch as the

 

 

LECS.

 

External

The LES is not on the same switch as

 

 

the LECS.

Local LES Instance

The Id of the LES on an Internal switch (this is not relevant

 

for an External switch location).

Number of Active

The number of current active clients (as reported by the

Clients

LES).

 

Time since Last Active

The time elapsed since the LES stopped being active (in

Msg

minutes).

 

Number of RESET

The number of Reset messages sent to the LES by the LECS.

messages sent to LES

A Reset is attempted to solve split situations

Number of RESET

The number of Reset messages actually received by the LES

messages rcvd to LES

from the LECS (see above).

Reset LES Allowed

The number of Resets to the LES that are allowed (relevant

 

only for a shared LES).

 

Number of ELANs

The number of ELANs that are attached to the LES.

attached to LES

 

 

 

 

 