LAN Emulation Redundancy Setup 221

Display LE Service Display parameters of the LES redundancy facility in the CoreBuilder 9000

Redundancy ATM Enterprise Switch. For more information, see “LAN Emulation Redundancy” on page 136 in the Operations Guide.

Command Actions

Enter menu sequence: (1) SYS: Platform config

(1) SET: Switch setup

(5) SLE: LE setup

(4) RDN: LE Service redundancy setup

(1) DLR: Show LES redundancy params

Direct access sequence: 1 1 5 4 1

Command Result

System action taken: The LES redundancy parameters are displayed.

System message display: Information is displayed as shown in the example.

Example

Enter: 1 1 5 4 1

The following information is displayed:

LANE Service redundancy mechanism : Enabled

Startup Delay (Sec)

: 600

LES Redundancy Parameters

Table 28 shows the LES Redundancy Parameters displayed by the command.

.

Table 28 LES Redundancy Parameters

Name

Description

 

 

LANE Service Redundancy Status

Whether LANE service redundancy is enabled

 

or disabled.

Startup Delay

Time elapsed between switch startup and

 

startup of LANE redundancy facility — in

 

seconds. Default is 600.

 

 

Page 221
Image 221
3Com 9000 manual LES Redundancy Parameters