Setting Optimization Metrics 379

Set Optimization for Sets the Non Real Time Variable Bit Rate (VBR) optimization parameter. A NonRealTime-VBRchange to the NrtVBR optimization parameter takes place immediately.

Command Actions

Enter menu sequence:

(1) SYS: Platform Configuration

 

(1) SET: Switch setup

 

(9) PNI: PNNI Setup

 

(4) CFP: Configure PNNI

 

(3) NCF: Node Configuration

 

(5) OPT: Optimization Metrics

 

(2) SOP: Set Optimization

 

Metrics

 

(3) ONV: Optimization for

 

NonRealTime-VBR

Enter a parameter at the prompt

Parameter

Format or Range

constant bit rate

0 - 6

Direct access sequence:

1 1 9 4 3 5 2 3 [parameters]

Command Result

System action taken:

System message display:

The non real time VBR optimization parameter is displayed and is updated to its new value.

Default value is <x>. New value is

<y>.

Example

Enter: 1 1 9 4 3 5 2 3 2

The following message is displayed:

Default Value is ‘3 - opt_ctd’, New value is ‘2 - opt_av_cr’

Press ENTER to continue...

The value of the NonRealTime-VBR optimization parameter is updated to 2.

Page 379
Image 379
3Com 9000 manual 9 4 3 5 2 3 parameters