Signaling Timers 187
Example
Enter: 1 1 4 4 3.1.2
The following information is displayed (1-9 are timers, 10-13 are configuration parameters):
Signaling QSAAL Timers (Tenths of second):
for port <3.1.2>
Param number Param name Current
value
-------- ------------------------------ -------
1 Poll UNI 3.0 1
2 Keep alive UNI 3.0 10
3 No response UNI 3.0 100
4 CC UNI 3.0 10
5 Poll UNI 3.1 9
6 Keep alive UNI 3.1 10
7 No response UNI 3.1 70
8 CC UNI 3.1 10
9 Idle UNI 3.1 150
10 Sscop max CC 5
11 Sscop max PD 10
12 Sscop max stat 67
13 Sscop window 16