362CHAPTER 11: CONFIGURING AND MANAGING PNNI

Set PTSE Lifetime Sets the PTSE lifetime factor value. The PTSE lifetime factor is the value Factor used to calculate the initial lifetime of a PTSE. The PTSE refresh interval is

multiplied by this percentage to obtain the initial lifetime factor. A change to the PTSE lifetime factor value takes place after the next reboot.

Command Actions

Enter menu sequence:

(1) SYS: Platform Configuration

 

(1) SET: Switch setup

 

(9) PNI: PNNI Setup

 

(4) CFP: Configure PNNI

 

(3) NCF: Node Configuration

 

(4) TIM: Timers

 

(6) PLT: PTSE Lifetime Factor

Enter a parameter at the prompt

Parameter

Format or Range

lifetime factor

101% - 1000%

Direct access sequence:

1 1 9 4 3 4 6 [parameters]

Command Result

System action taken:

System message display:

The Hello inactivity factor is displayed and is updated to its new value.

Default value is <x>, new value is <y>

Example

Enter: 1 1 9 4 3 4 6 150

The following message is displayed:

Default Value is 200, new value is 150

Press ENTER to continue...