362 CHAPTER 11: CONFIGURING AND MANAGING PNNI
Set PTSE Lifetime
Factor Sets the PTSE lifetime factor value. The PTSE lifetime factor is the value
used to calculate the initial lifetime of a PTSE. The PTSE refresh interval is
multiplied by this percentage to obtain the initial lifetime factor. A change
to the PTSE lifetime factor value takes place after the next reboot.
Command Actions
Command Result
Example
Enter: 1 1 9 4 3 4 6 150
The following message is displayed:
Default Value is 200, new value is 150
Press ENTER to continue...
Enter menu sequence: (1) SYS: Platform Configuration
(1) SET: Switch setup
(9) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(6) PLT: PTSE Lifetime Factor
Enter a parameter at the prompt
Parameter Format or Range
lifetime factor 101% - 1000%
Direct access sequence: 1 1 9 4 3 4 6 [parameters]
System action taken: The Hello inactivity factor is displayed and is updated
to its new value.
System message display: Default value is <x>, new value is <y>