Install a Chassis Control Module

Install a Chassis Control Module

 

The G10 CMTS chassis accommodates a maximum of two Chassis Control Modules in slots 6

and 7. To install a Chassis Control Module, follow the same procedure described in “Install a

DOCSIS Module” on page 103.

 

 

Install a Hard Disk Module

 

 

 

 

You must install a Hard Disk Module opposite each installed Chassis Control Module. To

install a Hard Disk Module, follow the same procedure described in “Install an HFC Connector

Module or SIM” on page 105.

 

 

 

 

 

 

 

 

Install a NIC Module

 

 

 

 

 

 

 

 

 

 

The G10 CMTS chassis accommodates a maximum of two NIC Modules in slots 5 and 9 for

domain A and domain B. NIC Modules are shipped from the factory with two multimode

GBIC modules installed. If you are using a different GBIC module interface, you need to

replace the multimode GBIC modules that are shipped with the NIC Module. We recommend

that you remove and install the GBIC modules while the NIC Module is installed in the

chassis.

 

 

 

 

To install a NIC Module, follow this procedure:

 

 

 

 

1.

Follow the same procedure described in “Install a DOCSIS Module” on page 103. If you

 

will be using a GBIC module interface other than multimode, proceed to step 2.

 

 

Otherwise, you have completed the installation of the NIC Module.

 

 

 

 

 

2.

Remove each multimode GBIC module by squeezing the metal clasps at the top and

 

bottom of the GBIC module towards the module and firmly pull out the module until it is

 

 

removed from its slot.

 

 

 

 

 

3.

With the label side of the GBIC module facing the right, slide each replacement module

 

into its NIC Module slot until the metal clasps at the top and bottom of the GBIC module

 

 

click into place.

 

 

 

 

 

 

 

 

 

 

 

The GBIC module can be installed only one way. If you

 

 

 

 

 

 

orient the module in its slot incorrectly, it will stop about

 

 

 

 

 

 

halfway into the slot. If this occurs, remove the GBIC

 

 

 

 

 

 

module, rotate it 180°, and reinstall it.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install a NIC Access Module

You must install a NIC Access Module opposite each installed NIC Module. To install a NIC

Access Module, follow the same procedure described in “Install an HFC Connector Module or

SIM” on page 105.

 

 

 

 

 

 

 

108

JUNOSg 3.0 G10 CMTS Hardware Guide

Page 124
Image 124
Juniper Networks G10 CMTS Install a Chassis Control Module, Install a Hard Disk Module, Install a NIC Access Module, 108