G10 CMTS Management

G10 CMTS Management

 

The G10 CMTS supports the following system management applications and tools:

 

! Command-Line Interface (CLI)—The CLI provides the most comprehensive controls and

is instrumental for installation, configuration, troubleshooting, and upgrade tasks.

 

! SNMP—The CMTS can interact with SNMPv2c and SNMPv3-based Network

Management Systems using DOCSIS 1.0 and DOCSIS 1.1 MIBs and enterprise MIBs.

Events can conditionally be reported as system log messages or SNMP traps.

 

! ServiceGuard Management System – This optional advanced diagnostics application

with a Java GUI provides a rendition of a spectrum analyzer for acquiring data on

upstream transmission cable performance. It incorporates an integrated Impairment

Identification tool that allows for unattended monitoring of statistics to characterize

compromised performance to a potential cause (such as impulse or burst noise, narrow

band ingress, or microreflections).

 

 

G10 CMTS Hardware Overview

 

This section provides an overview of the modules and various hardware components of the

G10 CMTS and where they reside within the chassis. This overview presents material that is

specific to the installation and configuration of the G10 CMTS.

 

Figure 4 on page 11 illustrates a front view of a fully configured chassis. Figure 5 on page 12

illustrates a front view of a partially configured chassis in which DOCSIS Modules, a Chassis

Control Module (CCM), a Network Interface Card (NIC) Module, power supplies, air

management modules, and power supply filler panels have been removed. Figure 6 on

page 13 illustrates a rear view of a fully configured chassis that uses the AC power transition

module and HFC Connector Modules (see Figure 39 on page 122 for an illustration of the DC

power transition module). Figure 7 on page 14 illustrates the rear view of the partially

configured chassis in which HFC Connector Modules, a Hard Disk Module, a NIC Access

Module, and air management panels have been removed. Figure 8 on page 15 provides a top

view of the chassis midplane showing the slot numbering and the location of each module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

JUNOSg 3.0 G10 CMTS Hardware Guide

 

Page 26
Image 26
Juniper Networks G10 CMTS manual G10 Cmts Management, G10 Cmts Hardware Overview