Noise Measurement Methodology

Figure 23: Average Upstream Noise Measurement Example

Peak Upstream Noise Measurement

This section defines a procedure for taking the peak upstream noise measurements required

as part of the RF plant and HFC environment characterization. We recommend that you take

a sample of 10 percent of the nodes terminated at the installation site. Table 34 provides the

appropriate setup configuration settings for the HP 8591C spectrum analyzer.

 

 

Table 34: Peak Noise Spectrum Analyzer Setup

 

 

 

 

Setting

 

Value

 

 

 

Start frequency

 

2 MHz

 

 

 

 

Stop frequency

 

45 MHz

 

 

 

 

 

Resolution bandwidth

 

100 kHz

 

Video bandwidth

 

30 kHz

 

 

 

 

Scale

 

5 dB/div

 

 

 

 

 

Internal amplifier

 

Off

 

 

 

 

 

Attenuator

 

0 dB

 

 

 

Reference level of headend

 

0 dBmV

 

 

 

 

Max Hold

 

1 minute

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Connect the spectrum analyzer to the selected upstream signal at the upstream splitter

 

or at the CMTS upstream port.

 

 

 

 

 

 

 

2.

Configure the spectrum analyzer using the values defined in Table 34.

 

 

 

 

3.

Start the measurement.

 

 

 

 

After completing the measurement, the analyzer display should resemble Figure 24 on

page 85.

 