Data Path Processing

Upstream Data Path

 

Following is a description of the flow of a packet through the upstream data path of a DOCSIS

Module:

 

1. If you have configured and applied a subscriber management or IEEE 802.1 input filter,

a packet received on a cable interface of a DOCSIS Module is evaluated based on the

filter configuration and is either dropped or passed.

 

2. If the packet is not dropped by an input filter, it is classified to an ingress unit and either

bridged (Layer 2) or forwarded (Layer 3), depending on the configuration of the ingress

unit, to the egress unit.

 

3. If you have configured and applied a subscriber management or IEEE 802.1 output filter,

the packet is evaluated based on the filter configuration and is either dropped or passed.

 

4. If the packet is not dropped by the output filter, it is sent to QoS processing, where it is

ordered and scheduled based on its QoS parameters and the traffic scheduling policy

you have configured. If you have configured a congestion management policy, the

packet might be dropped, depending on its projected queue traversal latency.

 

5. The packet is transmitted to either the NSI or the HFC network on the physical interface

associated with the egress unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 