Power On and Configure the PC

described in step 8 (see Figure 17 on page 49). Table 44 indicates the expected status of all the LEDs on the NIC Access Module’s rear panel following power-on. If the OPERATION LED is not illuminated green, the NIC Access Module is considered faulty and you might have to replace it (see the “Remove a NIC Access Module” on page 170).

Table 44: NIC Access Module LED Status

LED

Post-initialization Status

Meaning

 

 

 

POWER

Green

Power is applied.

 

 

 

OPERATIONAL

Green

Successful initialization.

 

 

 

INT FAULT

Off

No internal failure.

 

 

 

EXT FAULT

Off

No external failure.

 

 

 

 

Amber

One or more of the FE or GE ports is

 

 

enabled, but unused.

 

 

 

Before you replace any module that appears to be faulty based on its LED status, contact Juniper Networks customer support for technical assistance.

Power On and Configure the PC

1.Power on the personal computer (PC) attached to the serial port of the Chassis Control Module.

2.Launch your asynchronous terminal emulation application (such as Microsoft WindowsHyperterminal), and establish a direct connection. Configure the port settings as follows:

!Bits per second: 9600

!Data bits: 8

!Parity: None

!Stop bits: 1

!Flow control: None

Connect the Power and Perform Initial Configuration

127