Juniper Networks G10 CMTS manual DC Power, G10 Cmts Environmental Specifications

Models: G10 CMTS

1 210
Download 210 pages 10.01 Kb
Page 88
Image 88

Environment

DC Power

 

The G10 CMTS requires a DC power source that operates within a voltage range of –36 to

–75 VDC. Unlike the AC configuration, the DC power transition modules do not operate

independently. Each DC power transition module supports the power supplies in both

domains of the chassis. If one DC power transition module fails, all the current for the system

must be supplied from a single power source. Therefore, within the United States, a 50 A

circuit breaker (36 A maximum, plus margin) must be used with each of the two independent

DC power sources connected to the CMTS. Outside the United States, each DC power source

must have circuit breaker protection to account for a maximum current of 36 A, plus

additional margin required by local regulations.

 

Use the factory-supplied DC power cord ring lugs, and wire according to your local code for

the DC power cord connection to the G10 CMTS.

 

 

Environment

 

The installation site must meet the specifications provided in Table 25 to maintain the proper

environmental conditions for the G10 CMTS.

 

 

Table 25: G10 CMTS Environmental Specifications

 

 

 

Parameter

Condition

Requirement

 

 

 

Temperature

Ambient operating

0° to +40°C (0° to +104°F)

 

Ambient non-operating

–35° to +60°C (–31° to +140°F)

 

 

 

Humidity

Ambient operating and non-operating

10% to 90% (non-condensing)

 

 

 

Altitude

Operating and non-operating

0 to 3048 m (10,000 ft)

 

 

 

Vibration

Operating

5 Hz to 200 Hz, at 1.0g (1.0 oct/min)

 

 

 

 

Non-operating

5 Hz to 200 Hz, at 1.0g (1.0 oct/min)

 

 

200 Hz to 500 Hz, at 2.0g (1.0 oct/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72