Juniper Networks G10 CMTS manual Through the Chassis Control Module

Models: G10 CMTS

1 210
Download 210 pages 10.01 Kb
Page 54
Image 54

Chassis Control Module

Functional Characteristics

 

The Chassis Control Module contains a 6 U (267 mm) x 340 mm card with a 4 HP (20 mm),

single-wide front panel. The module installs from the front of the chassis and is

hot-swappable. A Chassis Control Module must be installed in slot 6 or slot 7. These slots and

the Chassis Control Module are keyed so no other module can be installed in slot 6, and the

Chassis Control Module cannot be installed in any other slots.

 

The Chassis Control Module is the single access point to the G10 CMTS for a command-line

interface or SNMP management application from a remote location. The Fast Ethernet port

Eth0 is used for this purpose. For connecting to the Chassis Control Module locally, use the

Eth0 port or the RS-232 COM port on the front panel. All DOCSIS Modules can be managed

through the Chassis Control Module.

 

The primary functions of the Chassis Control Module are as follows:

 

! Store and report configuration and alarm status on DOCSIS Modules and itself.

 

! Supply software images to all DOCSIS Modules.

 

! Serve as the SNMP agent for the CMTS.

 

! Provide the command-line interface.

 

! Run the CMTS’s Routing Engine.

 

! Support the subscriber account management (SAM) interface.

 

! Monitor the state of power supply and fan modules (see “Cooling and Fans” on page 29).

 

The Chassis Control Module contains a 500 MHz, Pentium III processor, 512 MB of RAM, and

256 MB CompactFlash, all delivering 1,300 MIPS of performance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

JUNOSg 3.0 G10 CMTS Hardware Guide

 

Page 54
Image 54
Juniper Networks G10 CMTS manual Through the Chassis Control Module