Features for Troubleshooting

You should consider the following general guidelines when interpreting the flap list statistics:

 

 

! If the flap list statistics are the opposite of the values presented in Table 45, the

provisioning and the HFC plant conditions are considered satisfactory. Use these values

to establish an operational baseline.

 

 

! If you sort the flap list by the total number of flaps, or by a specific flap, you can locate

problematic nodes in the HFC plant. For example, if the flap list is sorted by MERavg and

the flap entries with the lowest MERavg values are all within the same cable interface,

your diagnostic procedures can focus on a particular area of the return path.

 

 

! If you sort the flap list by MAC address (by-mac), you can reveal issues associated with

cable modems manufactured by the same vendor. You can determine this by inspecting

the unique vendor identifier contained in the first 24 bits of the MAC address.

 

 

! MERavg provides a good metric for the overall quality of the return path because it is

affected by virtually every possible source of QPSK and QAM signal amplitude and phase

distortion (unlike other metrics are affected mostly by noise). You can use MERavg to

gauge the margin of failure available within a particular upstream interface.

 

 

! If the IM value is high and the SM value is low, the cable modem might be having

problems with the following:

 

 

!

Initial ranging due to CMTS configuration issues.

 

 

!

Initial ranging due to HFC plant issues in the forward path or the return path.

 

 

!

Registration due to provisioning issues.

 

 

!

Stability.

 

 

! If the IM value is low and the SM value is high, then the cable modem is able to

successfully register, but there might be intermittent HFC plant issues in the forward

path or the return path that cause the cable modem to use periodic maintenance

opportunities unsuccessfully.

 

 

! A high PAdj value indicates that a cable modem’s power adjustment is changing by a

significant amount, which suggests problems in the return path. Compare PAdj for cable

modems that reside before and after an amplifier in the return path to provide an

indication of amplifier issues. High power levels of an RF signal can lead to laser

clipping, which results in corrupted codewords as seen by the CMTS. Therefore, a high

PAdj value in conjunction with a high CERavg value might provide an indication of laser

clipping.

 

 

! A high FAdj value can occur when you use a frequency stacking multiplexer (sometimes

called block upconversion) in which multiple upstream spectrums are stacked in

frequency at the fiber node in the upstream, and there is significant frequency error

introduced in the upconversion and downconversion process. Cable modems that have

degraded frequency stability also cause frequency adjust flaps to occur.

 

 

 

 

 

 