Juniper Networks G10 CMTS manual Power Transition Modules

Models: G10 CMTS

1 210
Download 210 pages 10.01 Kb
Page 44
Image 44

Chassis

Table 7: Power Supply Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

 

 

Output

Maximum

 

Type

Input Voltage

Input Current Rating

Voltage

Output Current

 

 

 

 

 

 

 

 

 

AC

90 to 240 VAC

2.5 A Nom (110 V, 70 percent efficiency)

+5.0 VDC

25.0 A

 

 

 

 

47 to 63 Hz

 

 

 

 

 

 

 

 

+3.3 VDC

35.0 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+12.0 VDC

8.0 A

 

 

 

 

 

 

 

 

 

 

 

 

 

–12.0 VDC

1.5 A

 

 

 

 

 

 

 

 

 

DC

–36 to –72 VDC

6.0 A Nom (–48 VDC)

+5.0 VDC

25.0 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+3.3 VDC

35.0 A

 

 

 

 

 

 

 

 

 

 

+12.0 VDC

8.0 A

 

 

 

 

 

 

 

 

 

 

 

 

 

–12.0 VDC

1.5 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The +5.0 VDC and +3.3 VDC outputs supply a combined maximum of 175 W using load

 

sharing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You cannot use a 250 watt AC power supply and a

 

 

 

 

 

200 watt AC power supply in the same G10 CMTS chassis.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Transition Modules

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The external power sources for the CMTS connect to the power transition modules. Two

 

 

power transition modules install from the rear of the chassis and plug into the midplane

 

 

opposite the power supplies in the front (see Figure 6 on page 13). The power transition

 

 

modules are provided for either AC or DC power sources, depending on how the chassis is

 

 

configured.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The outputs of the AC and DC power transition modules are wired differently within the

 

 

midplane. An AC power transition module only supports the five power supplies within its

 

 

domain. However, because the outputs of each DC power transition module are wired

 

 

together along the midplane, each DC power transition module supplies power to all 10 DC

 

 

power supplies in the chassis.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full power redundancy consists of redundant power supplies, power transition modules, and

 

 

power sources. All G10 CMTS systems are shipped with two power transition modules

 

 

installed, one per domain, to implement power transition module redundancy. This also

 

 

facilitates power source redundancy. You must supply power from different circuits to each

 

 

power transition module to implement power source redundancy.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Each AC module has a double-pole rocker switch that serves as a power switch for the

 

 

chassis. The switch is recessed to prevent accidental activation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The AC panel has a standard IEC 15-A receptacle with a three-prong male plug for connecting

 

 

to a power source. The DC panel has a 40-A terminal block with barrier guards for single lug

 

 

connections to the source and return.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

JUNOSg 3.0 G10 CMTS Hardware Guide

 

Page 44
Image 44
Juniper Networks G10 CMTS manual Power Transition Modules