G10 CMTS Installation Checklist

Step

Page Number

Completion Status

 

 

 

Install a Chassis Control Module and a Hard Disk Module

 

 

 

 

 

 

 

Remove the air management module where the Chassis Control Module will be inserted

page 108

 

 

 

 

Release the ejectors, align to the card guides, insert the Chassis Control Module, and

 

 

close the ejectors

 

 

 

 

 

Tighten the self-contained screws

 

 

 

 

 

 

 

Remove the air management panel where the Hard Disk Module will be inserted

 

 

 

 

 

 

 

Release the ejectors, align to the card guides, insert the Hard Disk Module, and close the

 

 

ejectors

 

 

 

 

 

Tighten the self-contained screws

 

 

 

 

 

Install a NIC Module and a NIC Access Module

 

 

 

 

 

Remove the air management module where the NIC Module will be inserted

page 108

 

 

 

 

 

Release the ejectors, align to the card guides, insert the NIC Module, and close the

 

 

 

 

ejectors

 

 

 

 

 

Tighten the self-contained screws

 

 

Remove the air management panel where the NIC Access Module will be inserted

 

 

 

 

 

Release the ejectors, align to the card guides, insert the NIC Access Module, and close

 

 

 

 

the ejectors

 

 

 

 

 

Tighten the self-contained screws

 

 

 

 

 

 

 

Cable an HFC Connector Module or SIM

 

 

 

 

 

 

 

Determine how the cable plant nodes will be connected to the downstream and

page 109

 

upstream ports of the module

 

 

Connect each of the four downstream ports to its respective node

 

 

 

 

 

Connect each of the four upstream ports to its respective node

 

 

 

 

 

 

 

Dress all cables appropriately

 

 

 

 

 

 

 

Cable a Chassis Control Module

 

 

Thread the Ethernet cable through the cable channel from the rear of the chassis

page 113

 

 

 

 

Connect the RJ-45 connector of the Ethernet cable to the Eth0 port on the Chassis

 

 

 

 

Control Module

 

 

 

 

 

 

 

Connect the other end of the Ethernet cable to its respective network equipment in the

 

 

 

 

headend

 

 

 

 

 

 

 

Cable a NIC Module and a NIC Access Module (if applicable)

 

 

 

 

 

 

 

Thread the network cables through the cable channel from the rear of the chassis

page 113

 

 

 

 

Connect each of the two Gigabit Ethernet network cables to the ports on the NIC

 

 

Module

 

 

 

 

 

Connect the other ends of the network cables to their respective network equipment in

 

 

 

 

the headend

 

 

 

 

 

Connect the RJ-21 end of the NIC Access Module cable into the NIC Access Module and

 

 

 

 

tighten the cable retainer screws

 

 

 

 

 

Connect eight RJ-45 connectors of the NIC Access Module cable to a maximum of four

 

 

 

 

HFC Connector Module

 

 

 

 

 

 

 

Dress all cables appropriately

 

 

 

 

 

 

 

Attach a PC to the Chassis Control Module

 

 

Connect the serial cable to the COM port on the Chassis Control Module

page 119

 

 

 

 

Connect the other end of the serial cable to the serial port on the PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prepare the Site

91

 

Page 107
Image 107
Juniper Networks G10 CMTS manual Step Number Completion Status