Juniper Networks G10 CMTS manual Terminal block. The guard will be reinstalled in step

Models: G10 CMTS

1 210
Download 210 pages 10.01 Kb
Page 137
Image 137

DC Power

Connect to Power Sources

 

 

 

 

 

 

 

 

Each DC power transition module in the G10 CMTS chassis contains a terminal block for

connecting to a DC power source (see Figure 39 on page 122). Unlike the AC configuration,

the DC power transition modules do not operate independently. Each DC power transition

module supports the power supplies in both domains of the chassis.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You must supply power from different circuits to domain A

 

 

 

 

 

 

and domain B for power redundancy protection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To connect the DC power transition modules to their power sources, follow this procedure:

 

 

 

 

1.

The G10 CMTS is shipped with ring lugs that are used to connect the DC power cord to

 

the DC power transition module terminal block. You must crimp these ring lugs to the

 

 

negative (–) and positive (+) wires of the DC power cord in order to properly connect to

 

 

the DC power transition module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

We recommend you use 10–12 AWG wires for your power

 

 

 

feeds unless your local safety code states otherwise.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Remove the plastic guard over the DC terminal block by loosening the two fastening

 

screws until the guard can be removed by sliding it upward and over the two screws (see

 

 

Figure 39 on page 122; the guard in this illustration is transparent so that you can see

 

 

the terminal block). The guard will be reinstalled in step 7.

 

 

 

 

 

3.

Remove the screw from the negative (–) terminal on the terminal block of the DC power

 

transition module. Insert the screw through the ring lug of the power cord that will be

 

 

attached to the negative (–) terminal of the DC power source and tighten the screw into

 

 

the negative (–) terminal on the terminal block. Apply 20 in-lb of torque to the screw.

 

 

 

 

 

4.

Remove the screw from the positive (+) terminal on the terminal block of the DC power

 

transition module. Insert the screw through the ring lug of the power cord that will be

 

 

attached to the positive (+) terminal of the DC power source and tighten the screw into

 

 

the positive (+) terminal on the terminal block. Apply 20 in-lb of torque to the screw.

 

 

 

 

 

5.

Connect the other end of the power cord connected to the negative (–) terminal on the

 

terminal block of the DC power transition module to the negative (–) terminal of the DC

 

 

power source in accordance with the manufacturer’s specifications.

 

 

 

 

 

6.

Connect the other end of the power cord connected to the positive (+) terminal on the

 

terminal block of the DC power transition module to the positive (+) terminal of the DC

 

 

power source in accordance with the manufacturer’s specifications.

 

 

 

 

 

7.

Replace the plastic guard over the two fastening screws and slide the guard down.

 

Tighten the screws using a torque of 2.5 in-lb.

 

 

 

 

 

Install the CMTS 121

Page 137
Image 137
Juniper Networks G10 CMTS manual Terminal block. The guard will be reinstalled in step