Downstream RF Measurement in CATV Mode

Downstream RF Measurement in CATV Mode

 

 

This section describes the procedure for measuring the downstream signal power from the

G10 CMTS using CATV mode on the HP8591C CATV analyzer. If your spectrum analyzer does

not support CATV mode, you can use the spectrum analyzer mode as described in

“Downstream RF Measurement in Spectrum Analyzer Mode” on page 135.

 

 

To measure the downstream signal power using CATV mode, follow this procedure:

 

 

1. Connect the spectrum analyzer to a cable within the plant that carries the downstream

 

signal you are measuring. The signal originates from one of the downstream ports of the

 

HFC Connector Module or the SIM (DS0 through DS3).

 

 

2. View (or set) the output RF power level of the specific interface to be measured. You can

 

view the output power by issuing the show configuration command:

 

 

 

user@host> show configuration interfaces cd-virtual-slot/docsis-slot/downstream-interface

 

cable-options downstream

 

...

 

rf-power 61;

 

...

 

 

 

In this example, the output RF power level is set to 61 dBmV. If the rf-powerstatement is

 

 

not included in your configuration, the output RF power level defaults to 61 dBmV.

 

 

 

 

To set the output RF power level for a downstream interface, include the rf-power

 

 

statement at the [edit interfaces cd-virtual-slot/docsis-slot/downstream-interface

 

 

cable-options downstream] hierarchy level:

 

 

 

 

rf-power rf-power;

 

 

 

 

The downstream interface power level can be from 50 dBmV through 61 dBmV.

 

 

 

3.

Press the MODE key and set the spectrum analyzer to CABLE TV ANALYZER mode.

 

 

4.

Select CHANNEL MEAS (channel measurement) and enter the desired channel number.

 

For example, select channel 75, which corresponds to a center frequency of 531 MHz.

 

 

 

5.

Navigate to the third menu on the screen and select DIGITAL POWER. The spectrum

 

analyzer display should be similar to the display in Figure 40 on page 135.

 

 

 

6.

Ensure that the DIGITAL CHANNEL POWER shown at the bottom of the display is

 

 

approximately equal to the configured downstream power level, minus any attenuation

between the HFC Connector Module or SIM downstream port and the point at which

your measurement is taken in the cable plant. In this example, assume the attentuation

between the CMTS and the measurement point is approximately 13 dB. Therefore, the

expected measured value should be approximately 48 dBmV.

 

 

 

 

 

 

 

 

 

 

 

 

134 JUNOSg 3.0 G10 CMTS Hardware Guide