Husqvarna 308 Installation, Do not, under any circumstances, mount the, Important Information

Models: 305 308

1 74
Download 74 pages 31.6 Kb
Page 20
Image 20
Do not, under any circumstances, mount the

3. INSTALLATION

It is possible to let the low voltage cable cross the working area. The low voltage cable must be stapled down or buried, and the cutting height should be such that the blades on the blade disc can never come in contact with the low voltage cable.

Make sure the low voltage cable is laid along the ground and secured with pegs 30” (75 cm) apart. The cable must lie close to the ground so as not to be cut before the grass roots have grown over it.

The transformer must be placed where it is well ventilated and is not exposed to direct sunlight. The transformer must be placed under a roof.

It is recommended to use an earth fault-breaker when connecting the transformer to the wall socket.

The transformer must be mounted on a vertical surface, such as a wall or a fence. Screw the transformer in place using the two mounting eyelets. No screws are supplied. Select screws suitable for the material in question.

Do not, under any circumstances, mount the

 

transformer at a height where there is a risk it can be

 

submerged in water (at least 12” [30 cm] from the

min 30cm/12”

ground). It is not permitted to place the transformer

on the ground.

 

IMPORTANT INFORMATION

The low voltage cable must not under any circumstances be shortened or extended.

IMPORTANT INFORMATION

Place the low voltage cable so that the blades on the blade disc can never come in contact with it.

IMPORTANT INFORMATION

Use the plug to disconnect the charging station, for instance before cleaning or repairing the loop wire.

20 - English

Page 20
Image 20
Husqvarna 308, 305 manual Installation, Do not, under any circumstances, mount the, Important Information