Husqvarna 305 Symptoms, Cause, Action, The robotic lawn, mower has difficulty, docking with the

Models: 305 308

1 74
Download 74 pages 31.6 Kb
Page 65
Image 65
9.3 Symptoms

9. TROUBLESHOOTING

9.3 Symptoms

If your Automower® does not work as expected, follow the troubleshooting guide below.

There is a FAQ (Frequently Asked Questions) on www.automower.com which provides more detailed answers to a number of standard questions. It you still cannot find the reason for the fault, contact the local dealer.

Symptoms

Cause

Action

 

 

 

 

 

 

The robotic lawn

The boundary wire is not laid in a long

Check that the charging station has

mower has difficulty

straight line that is far enough out

been installed according to the

docking with the

from the charging station.

instructions in 3.2 Installation of the

charging station

 

charging station on page 17.

 

 

 

 

The guide wire is not inserted in the

It is absolutely critical for operation

 

slot at the bottom of the charging

that the guide wire is perfectly straight

 

station.

and is in the correct position under

 

 

the charging station. Therefore make

 

 

sure that the guide wire is always in

 

 

its slot in the charging station. See

 

 

3.6 Installation of the guide wire.

 

 

 

 

The charging station is on a slope

Place the charging station on a

 

 

surface that is entirely level. See

 

 

3.2 Installation of the charging station

 

 

on page 17.

 

 

 

Uneven mowing

The robotic lawnmower works too few

Increase the mowing time. See

results

hours per day.

6.3 Timer on page44.

 

 

 

 

The proportion setting is incorrect in

Check that the correct Proportion

 

relation to the layout of the working

value is selected. See 6.4 Installation

 

area

on page 45.

 

 

 

 

The shape of the working area

Also use Remote start 2 to steer the

 

requires the use of both Remote start

robotic lawnmower to a remote area.

 

1 and Remote start 2 for the robotic

See 6.4 Installation on page 45.

 

lawnmower to find its way to all

 

 

remote areas.

 

 

 

 

 

Working area too large.

Try limiting the working area or

 

 

extending the working time. See

 

 

6.3 Timer on page 44.

 

 

 

 

Dull blades.

Replace all the blades and screws so

 

 

that the rotating parts are balanced.

 

 

See 8.7 Blades on page 59.

 

 

 

 

Long grass in relation to the set

Increase the cutting height and then

 

cutting height.

successively lower.

 

 

 

 

Accumulation of grass by the blade

Check that the blade disc rotates

 

disc or around the motor shaft.

freely and easily. If not, screw off the

 

 

blade disc and remove grass and

 

 

foreign objects. See 8.4 Cleaning.

 

 

 

The robotic

The robotic lawnmower clock needs

Set the clock. See 6.6 Settings on

lawnmower runs at

to be set.

page 51.

the wrong time

 

 

The start and stop times for mowing

Reset the start time and stop time

 

 

are incorrect.

settings for mowing. See 6.3 Timer

 

 

on page 44.

 

 

 

English - 65

Page 65
Image 65