3. Controller Parameter Setup | HRView Function Manual |
3.3. Hi4a Controller
Hi4 controller has the same function as Hi3TB. However, rapid Baudrate speeds are added and screen structure is different.
(1)For Ethernet use:
Use FTP function for Ethernet file transmission/reception.
(2)For
Condition setup and constant setup should be the same as follows. When both
『Serial Port 1』 and 『Serial Port 2』 are set as “FileMng,” Serial Port 1 has a priority, and HRView communication can be done only with Serial Port 1.
The Baudrate of the Serial Port 1 should have the same setup as HRView setup. However, the rest of the options should be the same as follows.
『[PF2]: System』 → 『2: Controller Parameter』 → 『2: Serial ports』 → 『3: Serial port #1 (CNSIO)』
08:09:05 | *** Serial port#1 *** | A:0 S:4 |
| |||||
Baudrate = | ||||||||
Character length = <7, | 8 | > bit |
|
| ||||
Stop bit |
|
|
|
|
|
|
|
|
= < | 1 | ,2> bit |
|
| ||||
Parity bit | = < |
| Disable | ,Odd,Even > | ||||
Echo | = < | Disable | ,Enable > |
Serial port usage = < FileMng,Sens,LVS >
Press
>_
Complete