3. Controller Parameter Setup

HRView Function Manual

3.3. Hi4a Controller

Hi4 controller has the same function as Hi3TB. However, rapid Baudrate speeds are added and screen structure is different.

(1)For Ethernet use:

Use FTP function for Ethernet file transmission/reception.

(2)For RS-232C use:

Condition setup and constant setup should be the same as follows. When both

Serial Port 1and Serial Port 2are set as “FileMng,” Serial Port 1 has a priority, and HRView communication can be done only with Serial Port 1.

The Baudrate of the Serial Port 1 should have the same setup as HRView setup. However, the rest of the options should be the same as follows.

￿[PF2]: System2: Controller Parameter2: Serial ports3: Serial port #1 (CNSIO)

08:09:05

*** Serial port#1 ***

A:0 S:4

 

Baudrate = <-,19200,38400,57600,115200>

Character length = <7,

8

> bit

 

 

Stop bit

 

 

 

 

 

 

 

 

= <

1

,2> bit

 

 

Parity bit

= <

 

Disable

,Odd,Even >

Echo

= <

Disable

,Enable >

Serial port usage = < FileMng,Sens,LVS >

Press [SHIFT]+[<-][->] Key.

>_

Complete

3-6