![](/images/new-backgrounds/1145063/14506391x1.webp)
Error Messages
ida FS 250, Operator's Guide
10. Errors and Recovery
The following errors are related solely to the ida FS 250 and will appear as printed error messages. For some of the error messages, additional explanatory text may be printed out together with the error message.
10.1 ida FS 250 Error Messages
Error 8008 - Attention ! | Two devices on the same address |
Escape Sequence Error | Invalid ESC sequence has been sent |
| to the printer (see the section: Invalid |
| Escape Character) |
Error 4510 | Invalid SCS Control received |
Error 5004 | Initializing NVRAM |
Error 5005 | NVRAM failed |
Error 5006 | NVRAM initialized |
Error 50?? | CP Error |
In addition to the above messages, a number of Boot Error Messages may be generated.
10.1.1. Two Devices with Same Address
If two devices on the same twinax line has the same address, the printer will print an error message. To recover follow these steps:
1.Turn the power off
2.Check each device on the same line against the system configuration.
3.Change the device address accordingly.