POST Error Code FRU/Action
1207 1. Communications Cable
2. Dual Async Adapter/A
13XX 1. Game Adapter
1402
Printer not ready
Information only
1403
No paper error,or interrupt failure
Information only
1404
System board timeout failure 1. Run Enhanced Diagnostics
1405
Parallel adapter error 1. Run Enhanced Diagnostics
1406
Presence test error 1. RunEnhanced Diagnostics
14XX
Not listed above. Check printer before
replacing system board
1. Printer
2. System Board
15XX 1. SDLC Adapter
1692
Boot sequence error 1. Run FDISK to ensure at least one active
partition is set active
16XX 1. 36/38 WorkstationAdapter
1762
Hard disk drive configuration error 1. Run Configuration. (See “IBM Setup
Utility program” on page 9.)
1780 (Disk Drive 0)
1781 (Disk Drive 1)
1782 (Disk Drive 2)
1783 (Disk Drive 3)
1. Hard Disk Drive
2. System Board
3. Riser card
4. Hard Disk Cable
5. Power Supply
1800 PCI/PnP Error! No HardwareInterrupt
Available 1. RunSetup and verify PCI/ISA
configuration settings.
2. If necessary,set ISA adapters to Not
available to allow PCI adapters to
properly configure.
3. Remove any suspect ISAadapters.
4. Rerun diagnostics.
5. PCI Adapter
1801 PCI/PnP Error! No SpaceAvailable to
Shadow ROM 1. Run Setup and verify PCI/ISA
configuration settings.
2. If necessary,set ISA adapters to Not
available to allow PCI adapters to
properly configure.
3. Remove any suspect ISAadapters.
4. Rerun diagnostics.
5. PCI Adapter
Chapter7. Symptom-to-FRU Index 65