POST Error Code FRU/Action
212XX 1. SCSI Printer
2. Printer Cable
213XX 1. SCSI Processor
214XX 1. WORM Drive
215XXXC, 215XXXD, 215XXXE, 215XXXU
If an external device, and power-on LED is
off, check external voltages
1. CD-ROM Drive I
2. CD-ROM Drive II
Enhanced CD-ROM Drive II
Any CD-ROM Drive
3. SCSI Cable
4. SCSI Adapter or System Board
216XX 1. Scanner
217XX
If an external device, and power-on LED is
off, check external voltages
1. Rewritable Optical Drive
2. SCSI Adapter or System Board
3. SCSI Cable
218XX
Check for multi CD tray or jukebox 1. Changer
219XX 1. SCSI Communications Device
24201Y0, 24210Y0
Be sure wrap plug is attached 1. ISDN/2 Adapter
2. ISDN/2 WrapPlug
3. ISDN/2 Communications Cable
273XX 1. 1 Mbps Micro Channel
2. Infrared LAN Adapter
27501, 27503, 27506, 27507 1. ServerGuard Adapter
2. System Board
3. Riser card
27502, 27504, 27510, 27511, 27533, 27534,
27536, 27537 1. ServerGuard Adapter
27509 1. Remove redundant adapters, run Auto
Configuration program, then retest.
27512 1. WMSELF.DGSdiagnostics file is
missing
2. WMSELF.DGSdiagnostics file is incorrect
27535 1. 3V Lithium Backup Battery
2. ServerGuardAdapter
27554 1. Internal Temperatureout of range
2. ServerGuardAdapter
27555, 27556 1. ServerGuard Adapter
2. Power Supply
27557 1. 7.2V NiCad Main Battery Pack
2. ServerGuardAdapter
Chapter7. Symptom-to-FRU Index 73