POST Error Code FRU/Action
10480 1. Hard Disk Drive (ESDI)
2. Drive Cable
3. System Board
10481
ESDI drive D seek error 1. Run Enhanced Diagnostics
10482
Drive select acknowledgement bad 1. Run Enhanced Diagnostics
106X1 1. Check Configuration
2. Ethernet Adapter
10635 1. Power-off computer,wait ten seconds
then power-on the computer
2. Ethernet Adapter
10651, 10660 1. Check Cables
2. Ethernet Adapter
106XX
Not listed above 1. Ethernet Adapter
107XX 1. 5.25-inch External
Diskette Drive
2. 5.25-inch Diskette
Drive Adapter/A
109XX
Check the adapter cables 1. ActionMedia
Adapter/A
2. System Board
3. Riser card
112XX
This adapter does not have cache 1. SCSI Adapter
2. Any SCSI Device
3. System Board
4. Riser card
119XX 1. 3119Adapter
121XX 1. Modem Adapter
2. Any Serial Device
3. System Board
4. Riser card
136XX 1. ISDN Primary Rate Adapter
2. System Board
3. Riser card
137XX 1. System Board
141XX 1. Realtime Interface Coprocessor
Portmaster
Adapter/A
70 HardwareMaintenance Manual