IBM AT-FS202SC/FS2, AT-FS202SC/FS4 manual lists the maximum operating distances for the switches

Models: AT-FS202 AT-FS202SC/FS3 AT-FS201 AT-FS202SC/FS1 AT-FS202SC/FS4 AT-FS202SC/FS2

1 44
Download 44 pages 16.08 Kb
Page 11
Image 11

AT-FS20x Series Installation Guide

Table 1 lists the maximum operating distances for the switches.

Table 1 Maximum Operating Distances

 

100Base-FX

10/100Base-TX

Model

 

 

 

 

 

Maximum

 

Maximum

 

Connector

Operating

Connector

Operating

 

 

Distance1

 

Distance2

 

 

 

 

 

 

 

 

 

 

AT-FS201

ST

2 km (1.2 mi)

RJ-45

100 m (328 ft)

 

 

 

 

 

AT-FS202

SC

2 km (1.2 mi)

RJ-45

100 m (328 ft)

 

 

 

 

 

AT-

SC

15 km (9.3 mi)

RJ-45

100 m (328 ft)

FS202SC/

 

 

 

 

FS1

 

 

 

 

 

 

 

 

 

AT-

SC

40 km (24.8

RJ-45

100 m (328 ft)

FS202SC/

 

mi)

 

 

FS2

 

 

 

 

 

 

 

 

 

AT-

SC

75 km (46.5

RJ-45

100 m (328 ft)

FS202SC/

 

mi)

 

 

FS3

 

 

 

 

 

 

 

 

 

AT-

SC

100 km (62 mi)

RJ-45

100 m (328 ft)

FS202SC/

 

 

 

 

FS4

 

 

 

 

 

 

 

 

 

1.Maximum distance for 100 Mbps optical datalinks is dependent on the following factors: type of optical fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at the operating optical wavelength.

2.Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to TIA/EIA 568A Commercial Building Telecommunications Cabling Standard.

3

Page 11
Image 11
IBM AT-FS202SC/FS2, AT-FS201 lists the maximum operating distances for the switches, AT-FS20x Series Installation Guide