Troubleshooting

Make sure that the twisted-pair cable does not exceed 100 meters (328 feet) and that you are using a Category 3 or better cable for 10Base-T operation or a Category 5 or better cable for 100Base-TX operation.

For information about maximum operating distances, see Table 1 on page 3.

If the LNK/ACT LED for the fiber optic port is OFF, do the following:

Verify that the end-node connected to the port is ON and is operating properly.

Check that the fiber optic cable is securely connected to the fiber optic port on the switch and on the end-node.

Check that the end-node connected to the port is operating at 100 Mbps.

Check that the end-nodes connected to the switch are operating at the same duplex mode.

Make sure that the cable connected to the switch’s receiver port (RX) is connected to the end-node’s transmitter port (TX) and that the switch’s transmitter port (TX) is connected to the end-node’s receiver port (RX).

Test the attenuation on the fiber cable to ensure that it does not exceed acceptable values.

Verify that you are using the appropriate type of fiber optic cables and that you have not exceeded the maximum operating distances. For the maximum operating distances, refer to Table 1 on page 3 and for the cable types, refer to Table 3 on page 12, Table 4 on page 12, or Table 5 on page 14.

Check that the operating specifications of the fiber optic port on the end-node are compatible with the operating specifications of the fiber optic port on the switch. For the fiber optic port specifications, refer to refer to Table 1 on page 3 and for the cable types, refer to Table 3 on page 12, Table 4 on page 12, or Table 5 on page 14.

If you are still experiencing problems after testing and troubleshooting the installation, contact Allied Telesyn Technical Support for assistance. Refer to “Contacting Allied Telesyn” on page viii.