Controls–dip switches.

Freeze Sentinel (Requires room air sensor kit–RAVRMS)

When this switch is enabled (UP), it turns OFF the freeze sentinel protection feature. With the switch disabled (DOWN), the freeze sentinel is activated which automatically provides heat without user interface. This helps to prevent plumbing damage by turning the heater and

fans ON at 41° F and OFF at 46° F.

FREEZE S (Freeze Sentinel)

 

Constant ON Fan

When this switch is enabled (UP), it allows the fans to run continuously, at high speed, even if the unit is in the STOP position.

Care and Cleaning CONST FAN (Constant

ON Fan)

Occupancy Sensor

When this switch is enabled (UP), it allows the unit to utilize an infrared motion sensor and a door switch for occupancy detection. This feature allows an energy management system to be installed and operated in conjunction with

the unit.

OCCUPIED (Occupancy Sensor)

Troubleshooting Tips

Consumer Support

Duct

The duct select function allows the indoor fan to be operated at two variable fan speeds, depending on the duct length. When this switch is enabled (UP), the unit automatically selects either high or middle fan speed for longer ductwork applications. When set in the down position, the unit is automatically operated in either the middle or low fan speed for shorter ductwork applications.