GE 49-7419-2 Central Desk Control, Remote Thermostat, Safety Instructions, Operating Instructions

Models: 49-7419-2 AZ75H18EAC

1 28
Download 28 pages 41.01 Kb
Page 7
Image 7
Motion Sensor (Obtained locally)

GEAppliances.com

Motion Sensor (Obtained locally)

 

The Occupancy Sensor dip switch must be in

 

the up position to use this feature.

 

When connected, the wall mounted motion

 

sensor will detect motion in the room and

 

automatically cycle the unit between normal

 

operation and energy management operation.

Motion Sensor

The door and motion sensors work together to automatically cycle the unit between normal operation and energy management operation.

Door Sensor (Obtained locally)

The Occupancy Sensor dip switch must be in the up position to use this feature.

When connected, the door sensor will detect

 

when the door in the room is opened or closed.

 

This feature must be used in conjunction with

 

the motion sensor.

Door Sensor

 

The door and motion sensors work together to automatically cycle the unit between normal and energy management operations.

Central Desk Control

When connected, the unit lock-out is released and it can be turned ON or OFF with a switch located at the Central Desk Control. A separate wire pair must be run from each separate controlling switch to each individual Zoneline.

Central Desk Control

Safety Instructions

Operating Instructions

Care and Cleaning

Remote Thermostat

The unit will be controlled by a remote thermostat.

IMPORTANT:

The Zoneline thermostat connections provide 24V AC only.

If using a digital/electronic wall thermostat, you must set it to the 24V AC setting. See the Installation Instructions for the wall thermostat.

Door Sensor (Obtained locally) CAUTION:

Damage to a wall thermostat or to the Zoneline electronics can result from improper connections. Exercise extra attention when connecting blue and black wires. No line voltage connections should be made to any circuit in the thermostat. Isolate all wires in building from line voltage.

Red–24V AC only Central Desk Control

Green–Low Speed Fan

Green–High Speed Fan

Black–Reversing Valve

Yellow–Compressor

White–Heater

Common–Ground

7