Temperature Limiting (Requires room air sensor kit–RAVRMS)

Safety

Temperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. Temperature limiting is controlled by switches 1–6 on the top block

TL1 (C) (Temp. Limit 1–Cool)

TL2 (C) (Temp. Limit 2–Cool)

TL3 (C) (Temp. Limit 3–Cool)

of auxiliary controls. The first three switches are used to select the cooling limits. The next three switches are used to control the heating limits.

TL1 (H) (Temp. Limit 1–Heat)

TL2 (H) (Temp. Limit 2–Heat)

TL3 (H) (Temp. Limit 3–Heat)

Instructions

Operating Instructions

Temperature limiting during COOL mode

(all temperatures shown in °F)

 

UP

DOWN

Minimum
Maximum

 

 

NONE

1, 2, 3

60°

85°

 

 

1

2, 3

64°

85°

 

 

1, 2

3

66°

85°

 

 

2

1, 3

68°

85°

 

 

2,3

1

70°

85°

 

 

1, 2, 3

NONE

72°

85°

 

 

1, 3

2

74°

85°

 

 

3

1, 2

76°

85°

 

 

 

 

 

 

 

Temperature limiting during HEAT mode

(all temperatures shown in °F)

 

UP

DOWN

Minimum

Maximum

 

 

NONE

4, 5, 6

60°

85°

 

 

4

5, 6

60°

80°

 

 

4, 5

6

60°

78°

 

 

5

4, 6

60°

76°

 

 

5,6

4

60°

74°

 

 

4, 5, 6

NONE

60°

72°

 

 

4, 6

5

60°

70°

 

 

6

4, 5

60°

65°

 

 

 

 

 

 

 