GE AZ75H18EAC, 49-7419-2 4INSTALL AND CONNECT THE CASE, 5aINSTALL AND GROUND THE UNIT TO THE CASE

Models: 49-7419-2 AZ75H18EAC

1 28
Download 28 pages 41.01 Kb
Page 20
Image 20
4INSTALL AND CONNECT THE CASE

Installation Instructions

4INSTALL AND CONNECT THE CASE

1.Remove the front case panel and pull the unit out of the case. Place the empty case onto the platform in the closet with the outdoor side facing the wall plenum opening. Align the case to the plenum opening and attach with six screws.

2.Adjust all four leveling legs until the case is level.

Inside

 

wall

Rigid

 

ductwork

 

Air

 

discharge

 

outlet

 

Leveling legs

3.Using field-supplied screws, bolt the case to the platform.

4.Connect the internal or external drain as necessary.

Drain fitting 34

 

External

 

drain

Bolt case to

OR

Internal

platform

drain

5a INSTALL AND GROUND THE UNIT TO THE CASE

UNIT INSTALLED THROUGH FRONT OF CASE

1.Slide the back of the unit into the case. Push the unit all of the way into the case until it stops.

NOTE: Either of the case sides may be removed to enable the unit to be slid into the case.

2.Ground the unit to the case by installing the front case-to-unit hex-bolt and/or case-to-unit side screw.

Side screw

Hex bolt

5b INSTALL AND GROUND THE UNIT TO THE CASE

UNIT INSTALLED THROUGH SIDE

OF CASE

1.Slide the side of the unit into the case. Push the unit all of the way into the case until it stops.

NOTE: Either of the case sides may be removed to enable the unit to be slid into the case.

2.Attach the case side panel to the main case.

3.Ground the unit to the case by installing the front unit-to-case hex-bolt and/or case-to-unit side screw.

Side screw

 

(may be

 

installed on

Hex bolt

either side)

 

20

Page 20
Image 20