Installation Instructions
ELECTRICAL REQUIREMENTS
•Use ONLY the wiring size recommended for single outlet branch circuit.
•Proper current protection is the responsibility of the owner.
Recommended branch circuit wire sizes*
Nameplate | AWG Wire |
maximum circuit | size** |
breaker size |
|
|
|
15A | 14 |
20A | 12 |
30A | 10 |
AWG – American Wire Gauge
*Single circuit breaker from main box
**Based on copper wire, single insulated conductor at 60° C
NOTE: Use copper conductors only.
230/208 VOLT ELECTRICAL SUPPLY
A power supply kit must be used to supply power to the Zoneline unit. The appropriate kit is determined by the voltage, the means of electrical connection and the amperage of the branch circuit. See the POWER CONNECTION CHART on page 13 to select the appropriate kit.
Power supply kit
All wiring, including installation of the receptacle, must be in accordance with the NEC and local codes, ordinances and regulations.
Tandem | Perpendicular | Large Tandem |
15 Amp | 20 Amp | 30 Amp |
230/208 volt receptacle configuration
FOR 230/208 VOLT POWER CORD CONNECTIONS ONLY
1.Remove the front panel by taking out the four front screws, the upper two screws from the top of the panel and the shipping screws on each side, if present. (Discard the two side shipping screws, if present.)
Side
shipping screw
Side shipping screw
2.Remove the junction box cover and the junction box and discard.
Remove junction box and cover
3.Connect the power cord, with a loop, through the strain relief.
Strain relief
IMPORTANT: Power cord must have a loop.
11