IBM AT-FS201, AT-FS202 Maximum, Model, Cable Type, Operating, Allowable Loss, Distance, Budget

Models: AT-FS202 AT-FS202SC/FS3 AT-FS201 AT-FS202SC/FS1 AT-FS202SC/FS4 AT-FS202SC/FS2

1 44
Download 44 pages 16.08 Kb
Page 21
Image 21
Manual background

AT-FS20x Series Installation Guide

 

 

Maximum

Maximum

Model

Cable Type

Operating

Allowable Loss

 

 

Distance1

Budget

 

 

 

 

AT-FS202

50/125 or 62.5/

2 km (1.2 mi)

13 dB at 1310 nm

 

125 micron

 

 

 

multimode

 

 

 

 

 

 

AT-FS202SC/FS1

50/125 or 62.5/

2 km (1.2 mi)

13 dB at 1310 nm

 

125 multimode

 

 

 

 

 

 

 

9/125 micron

15 km (9.3 mi)

16 dB at 1310 nm

 

single-mode

 

 

 

 

 

 

AT-FS202SC/FS2

9/125 micron

40 km (24.8 mi)

30 dB at 1310 nm

 

single-mode

 

 

 

 

 

 

AT-FS202SC/FS3

9/125 micron

75 km (46.5 mi)

33 dB at 1310 nm

 

single-mode

 

 

 

 

 

 

AT-FS202SC/FS42

9/125 micron

100 km (62 mi)

34 dB at 1550 nm

 

single-mode

 

 

 

 

 

 

1.Maximum distance for 100 Mbps optical datalinks is dependent on the following factors: type of optical fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at the operating optical wavelength.

2.The cable must be non-dispersion-shifted, dispersion-shifted, or non-zero dispersion-shifted single-mode fiber optic cable.

Note

See “Fiber Optic Port Specifications” on page 22 for additional information on the fiber optic port.

13