Hot-Plug PCI Adapters

The function of hot-pluggable PCI adapters is to provide concurrent additions or removals of PCI adapters when the system is running. This function is explained in the following paragraphs.

In the chassis, the installed adapters inside the slots are protected by plastic separators, designed to prevent grounding and damage when adding or removing adapters. The hot-plug LEDs outside the chassis indicate if a adapter can be plugged in or removed from the system. These LEDs are also visible inside the chassis. Inside, the light from the LED is routed to the top of the plastic separators, using light pipes, which makes it very easy to locate the right slot. The hot-plug PCI adapters are secured with retainer clips on top of the slots; therefore, you do not need a screwdriver to add or remove a card and there is no screw to drop inside the chassis causing damage to the system.

The function of hot-plug is not only provided by the PCI slot, but also by the function of the adapter. Most adapters are hot-pluggable, but some are not. Be aware that some adapters must not be removed when the system is running, for example, the adapter with the operating system disks connected to it, or the adapter that provides the system console. Refer to the PCI Adapter Placement Reference Guide, SA38-0538 for further information.

To manage hot-plug PCI adapters, it is important to turn off slot power before adding, removing, or replacing the adapter, which is done by the operating system. There are three possibilities for managing hot-plug PCI slots in AIX:

Command line:

lsslot - List slots and their characteristics

drslot - Dynamically reconfigures slots

SMIT

WebSM

When working with the commands and tools mentioned above, the hot-plug LEDs (see Figure 2) change their state. Table 1 shows the possible states of the hot-plug LEDs.

Table 1. Hot-Plug LED Indications

LED Indication

PCI Slot Status

Definition

 

 

 

Off

Off

Slot power is off. It is safe to remove or

 

 

replace adapters.

 

 

 

On (not flashing)

On

Slot power is on. Do not remove or replace

 

 

adapters.

 

 

 

Flashing slowly (one

Identify

Indicates the slot has been identified by the

flash per second)

 

software; do not remove or replace adapters

 

 

at this time.

 

 

 

Flashing fast (six to

Action

Indicates the slot is ready for adding,

eight flashes per

 

removing, or replacing of adapters.

second)

 

 

 

 

 

To add a hot-plug PCI adapter use the drslot command to set the slot first into the Identify state (LED flashes slowly) to verity the right slot was selected. After pressing Enter, the LED changes its state to the Action state (LED flashes fast).